Original Research

Diagnostic Accuracy of Urine Reagent Strips for Rapid Bacterial Meningitis Diagnosis: A Cross-Sectional Validation Study in a Resource-Limited Setting

DOI https://doi.org/10.70302/jpsim.v7i4.2664
Received: 22 Oct 2026 Accepted: 20 Nov 2026 Published Online: 20 Nov 2026

Abstract

Objective:

To prospectively confirm the diagnostic performance of urine reagent strips in the detection of meningitis.

Methodology:

This cross-sectional study included patients aged 20–60 years with clinically suspected meningitis requiring lumbar puncture. The index test was a standardized urine reagent strip (Combur-10 Test®) applied to undiluted CSF, interpreted for leukocyte esterase, protein, and glucose according to manufacturer color gradings taking laboratory CSF analysis as gold standard test. Following parameters were statistically calculated for accuracy.

Results:

Among 105 enrolled patients (mean age 38.5 ± 12.2 years; 55.2% male), the prevalence of meningitis by reference standard was 60.0% (63/105). Against this gold standard, the reagent strip method demonstrated a sensitivity of 86.5% (95% CI: 75.8–93.1), specificity of 88.4% (95% CI: 74.1–95.6), positive predictive value of 91.5% (95% CI: 82.0–96.2), and negative predictive value of 82.6% (95% CI: 69.7–90.8). The diagnostic accuracy is 87.6% (95% CI: 79.9 – 92.9). The area under the ROC curve was 0.91 (95% CI: 0.86 – 0.96) which shows excellent discriminatory ability.

Conclusion:

Urine reagent strip are easily available, are cost effective and operationally feasible bedside diagnostic kits which can be used for a rapid diagnosis of meningitis in resource-limited settings.

Keywords:
Cerebrospinal Fluid Meningitis Point-of-Care Testing Reagent Strips Diagnostic Sensitivity and Specificity

How to Cite This Article

Bukhari SAH, Shaukat A, Ahmed U, Irfan M, Ahmad Z, Shaukat M. Diagnostic Accuracy of Urine Reagent Strips for Rapid Bacterial Meningitis Diagnosis: A Cross-Sectional Validation Study in a Resource-Limited Setting. J Pak Soc Intern Med. 2026;7(4):321–325. doi:10.70302/jpsim.v7i4.2664

⭳ Download XML (JATS)

Conflict of Interest

The authors declare no conflict of interest.

Disclosed in accordance with ICMJE and COPE guidelines.

Funding

This research received no specific grant from any funding agency.

Funder information follows the Crossref Funder Registry standard.

Author Contributions

SAHB: Conception.
AS, ZA: Design of the work.
UA, MI, MS: Data acquisition, analysis, or interpretation.
AS, UA, MI, MS: Draft the work.
SAHB, ZA: Review critically for important intellectual content.
All authors approve the version to be published.
All authors agree to be accountable for all aspects of the work.

Contributions are recorded against the ICMJE criteria for authorship.

Data Availability

Data are available from the corresponding author on reasonable request.

Ethics Statement

This study was approved by Institutional Review Board of Faisalabad Medical University. Approval number: 48.ERC/FMU/2024-25-35, dated March 05, 2025.

Conducted in accordance with the Declaration of Helsinki.

References

  1. Wunrow HY, Bender RG, Vongpradith A, Sirota SB, Swetschinski LR, Novotney A, et al. Global, regional, and national burden of meningitis and its aetiologies, 1990–2019: a systematic analysis for the Global Burden of Disease Study 2019. 2023;22(8):685–711.
  2. Greenwood B, Sow S, Preziosi MP. Defeating meningitis by 2030 – an ambitious target. Trans R Soc Trop Med Hyg. 2021;115(10):1099.
  3. Seale AC, Blencowe H, Manu AA, Nair H, Bahl R, Qazi SA, et al. Estimates of possible severe bacterial infection in neonates in sub-Saharan Africa, south Asia, and Latin America for 2012: a systematic review and meta-analysis. Lancet Infect Dis. 2014;14(8):731–41.
  4. Pak P, Med JJ, Sehran Khalid M, Arooj S, Asghar A, Mansoor A, et al. Diagnostic Accuracy Of Contrast Enhanced T2 Flair In Diagnosing Infective Meningitis Considering CSF Analysis As Gold Standard. Pak Postgrad Med J. 2023;34(03):125–30.
  5. van de Beek D, Cabellos C, Dzupova O, Esposito S, Klein M, Kloek AT, et al. ESCMID guideline: Diagnosis and treatment of acute bacterial meningitis. Clinical Microbiology and Infection. 2016;22:S37–62.
  6. Manjunath M, Tasneem R, Malathi B, Srujan H. Utility of Urine Reagent Strips for Analysis of Cerebrospinal Fluid in Emergency Settings: A Cross-sectional Study. J Clin Diag Res. 2022; 16(5):EC46-9.
  7. Dhakshinya M, Brundha MP. Use of Urinary Reagent Strips in Testing Cerebrospinal Fluid For Meningitis - A Review. Indian J Foren Med Toxicol. 2020;14(4):4933–40.
  8. R AG, H PM. Utility of Urine Reagent Strips in CSF Analysis as An Aid to Rapid Diagnosis of Meningitis. Ann Pathol Lab Med. 2020;7(6):A306-310.
  9. Deshpande T, Behera M, Anuradha S. Urinary reagent strips a rapid diagnostic tool for cerebrospinal fluid analysis: A study from Western India. Sri Lanka J Child Health. 2022;51(2):270–6.
  10. Joshi D, Kundana K, Puranik A, Joshi R. Diagnostic accuracy of urinary reagent strip to determine cerebrospinal fluid chemistry and cellularity. J Neurosci Rural Pract. 2013;4(2):140.
  11. Mahmoud A, Said N, El Kholy R, Elhag M. Role of urine reagent strips in diagnosis of childhood meningitis. Menoufia Med J. 2021;34(2):649.
  12. Moosa A, Ibrahim MD, Quortum HA. Rapid diagnosis of bacterial meningitis with reagent strips. Lancet. 1995;345(8960):1290–1.
  13. Wankhade R, Bhake A. Assessment of efficacy of urine reagent strips for cerebrospinal fluid analysis as emergency workup in critical care setup. J Datta Meghe Inst Med Sci Uni. 2020;15(4):526–32.
  14. Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig L, et al. STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies. BioMed J. 2015;351.
  15. Bortcosh W, Siedner M, Carroll RW. Utility of the urine reagent strip leucocyte esterase assay for the diagnosis of meningitis in resource-limited settings: meta-analysis. Trop Med Int Health. 2017;22(9):1072–80.
  16. Shah KH, Richard KM, Nicholas S, Edlow JA. Incidence of traumatic lumbar puncture. Acad Emerg Med. 2003;10(2):151–4.
  17. Drain PK, Hyle EP, Noubary F, Freedberg KA, Wilson D, Bishai WR, et al. Diagnostic point-of-care tests in resource-limited settings. Lancet Infect Dis. 2014;14(3):239–49.

Reference list indexed for Google Scholar and ResearchGate. DOI links resolve via doi.org.

CC BY CC BY 4.0 This article is published under the Creative Commons Attribution 4.0 International License. May be shared and adapted with attribution. Authors retain copyright. © 2026 The Author(s).